Check: TSS0680
zOS TSS STIG:
TSS0680
(in versions v6 r43 through v6 r30)
Title
PPEXP Control Option will be properly set. (Cat II impact)
Discussion
The PPEXP Control Option allows the site to specify a password expiration interval. In accordance with DODI 8500.2 for DOD information systems processing sensitive information and above, and CJCSM 6510.01, the following recommendations concerning password requirements are mandatory and apply equally to both classified and unclassified systems: The system-wide options control the default settings for determining how the ACP will function when handling requests for access to the operating system environment, ACP, and customer data. The ACP provides the ability to set a number of these fields at the subsystem level. If no setting is found, the system-wide defaults will be used. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment. In addition, failure to establish standardized settings for the ACP control options introduces the possibility of exposure during migration process or contingency plan activation.
Check Content
Refer to the following report produced by the TSS Data Collection: - TSSCMDS.RPT(STATUS) Automated Analysis Refer to the following report produced by the TSS Data Collection: - PDI(TSS0680) Note: Current DoD policy has changed requiring that the password change interval be at the most 60 days. Ensure that this is in effect. The PPEXP Control Option will conform to the following requirements. If the following guidance is true, this is not a finding. PPEXP(60)
Fix Text
The IAO will ensure that the PPEXP Control Option values are set to the values specified. Note: Current DoD policy has changed requiring that the password change interval be at the most 60 days. Ensure the PPEXP Control Option value conforms to the following requirements. PPEXP(60) Example: TSS MODIFY PPEXP(60)
Additional Identifiers
Rule ID: SV-48613r2_rule
Vulnerability ID: V-36852
Group Title: TSS0680
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000199 |
The information system enforces maximum password lifetime restrictions. |
Controls
Number | Title |
---|---|
IA-5(1) |
Password-based Authentication |