Check: 3.129
Windows 7 STIG:
3.129
(in versions v1 r32 through v1 r25)
Title
User Account Control for the built In admin runs in Admin Approval Mode (Cat II impact)
Discussion
This check verifies whether the built-in Administrator account runs in Admin Approval Mode.
Check Content
Analyze the system using the Security Configuration and Analysis snap-in. Expand the Security Configuration and Analysis tree view. Navigate to Local Policies -> Security Options. If the value for “User Account Control: Admin Approval Mode for the Built-in Administrator account” is not set to “Enabled”, then this is a finding. The policy referenced configures the following registry value: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \Software\Microsoft\Windows\CurrentVersion\Policies\System\ Value Name: FilterAdministratorToken Value Type: REG_DWORD Value: 1
Fix Text
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> “User Account Control: Admin Approval Mode for the Built-in Administrator account” to “Enabled”.
Additional Identifiers
Rule ID: SV-25116r1_rule
Vulnerability ID: V-14234
Group Title: UAC - Admin Approval Mode
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-002038 |
The organization requires users to reauthenticate upon organization-defined circumstances or situations requiring reauthentication. |
Controls
Number | Title |
---|---|
IA-11 |
Re-authentication |