Check: WINCC-000147
windows 7 iavm:
WINCC-000147
(in version v1 r32)
Title
The touch keyboard or input panel must not highlight keys as passwords are entered. (Cat III impact)
Discussion
The touch keyboard or input panel may highlight keys as passwords are entered, providing visibility to nearby persons, and compromising them.
Check Content
If the system does not have a touch screen, this is NA. If the system has a touch screen and the following registry values do not exist or are not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Registry path: \SOFTWARE\Policies\Microsoft\TabletTip\1.7\ Value Name: PasswordSecurityState Type: REG_DWORD Value: 1 Value Name: PasswordSecurity Type: REG_DWORD Value: 4 or 5 (1, 2, or 3 are a finding)
Fix Text
If the system does not have a touch screen, this is NA. Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Tablet PC -> Input Panel -> "Turn off password security in Input Panel" to at least "Enabled: Medium High".
Additional Identifiers
Rule ID:
Vulnerability ID: V-56421
Group Title:
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000206 |
Obscure feedback of authentication information during the authentication process to protect the information from possible exploitation and use by unauthorized individuals. |
Controls
Number | Title |
---|---|
IA-6 |
Authenticator Feedback |