Check: WINAU-100102
Win7 Audit:
WINAU-100102
(in version v1 r16)
Title
The Setup event log will be configured to a minimum size requirement. (Cat II impact)
Discussion
Inadequate log size will cause the log to fill up quickly and require frequent clearing by administrative personnel.
Check Content
Fix Text
Configure the policy value for Computer Configuration -> Administrative Templates -> Windows Components -> Event Log Service -> Setup -> “Maximum Log Size (KB)” to at minimum “Enabled:32768”.
Additional Identifiers
Rule ID: SV-36023r1_rule
Vulnerability ID: V-26581
Group Title: Maximum Log Size - Setup
Expert Comments
Expert comments are only available to logged-in users.
CCIs
CCIs tied to check.
Number | Definition |
---|---|
No CCIs are assigned to this check |
Controls
Controls tied to check. These are derived from the CCIs shown above.
Number | Title |
---|---|
No controls are assigned to this check |