Check: WN12-CC-000062
Windows 2012 IAVM:
WN12-CC-000062
(in version v1 r30)
Title
Remote Assistance log files must be generated. (Cat III impact)
Discussion
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. This setting will turn on session logging for Remote Assistance connections.
Check Content
If the following registry value does not exist or is not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \Software\Policies\Microsoft\Windows NT\Terminal Services\ Value Name: LoggingEnabled Type: REG_DWORD Value: 1
Fix Text
Configure the policy value for Computer Configuration -> Administrative Templates -> System -> Remote Assistance -> "Turn on session logging" to "Enabled".
Additional Identifiers
Rule ID:
Vulnerability ID: V-15707
Group Title:
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000366 |
Implement the security configuration settings. |
Controls
Number | Title |
---|---|
CM-6 |
Configuration Settings |