Check: WINER-000111
Windows 2003 DC STIG:
WINER-000111
(in version v6 r40)
Title
The system must be configured to collect unplanned Windows server shutdown events. (Cat II impact)
Discussion
Windows Error Reporting information can be used to help diagnose day-to-day software issues, as well as help discover malicious code and possibly zero-day attacks on systems. This setting includes unplanned shutdown events in error reporting.
Check Content
Fix Text
Configure the policy value for Computer Configuration -> Administrative Templates -> System -> Error Reporting -> Advanced Error Reporting settings -> "Report unplanned shutdown events" to "Enabled".
Additional Identifiers
Rule ID: SV-70829r1_rule
Vulnerability ID: V-56569
Group Title:
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001312 |
Generate error messages that provide information necessary for corrective actions without revealing information that could be exploited. |
Controls
Number | Title |
---|---|
SI-11 |
Error Handling |