Check: DS00.0151_2003
Windows 2003 DC STIG:
DS00.0151_2003
(in version v6 r37)
Title
The time synchronization tool must be configured to enable logging of time source switching. (Cat III impact)
Discussion
When a time synchronization tool executes, it may switch between time sources according to network or server contention. If switches between time sources are not logged, it may be difficult or impossible to detect malicious activity or availability problems.
Check Content
Verify logging is configured to capture time source switches. If the Windows Time Service is used, verify the following registry value. If it is not configured as specified, this is a finding. Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \System\CurrentControlSet\Services\W32Time\Config\ Value Name: EventLogFlags Type: REG_DWORD Value: 2 or 3 If another time synchronization tool is used, review the available configuration options and logs. If the tool has time source logging capability and it is not enabled, this is a finding.
Fix Text
Configure the time synchronization tool to log time source switching. If the Windows Time Service is used, configure the following registry value. Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \System\CurrentControlSet\Services\W32Time\Config\ Value Name: EventLogFlags Type: REG_DWORD Value: 2 or 3
Additional Identifiers
Rule ID: SV-54933r1_rule
Vulnerability ID: V-8324
Group Title:
Expert Comments
CCIs
| Number | Definition |
|---|---|
| CCI-000366 |
Implement the security configuration settings. |
Controls
| Number | Title |
|---|---|
| CM-6 |
Configuration Settings |