Check: VNSX-ND-000100
VMware NSX Manager STIG:
VNSX-ND-000100
(in version v1 r1)
Title
The NSX Manager must compare internal information system clocks at least every 24 hours with an authoritative time server. (Cat III impact)
Discussion
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside of the configured acceptable allowance (drift) may be inaccurate. Additionally, unnecessary synchronization may have an adverse impact on system performance and may indicate malicious activity. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.
Check Content
Verify NSX Manager has the primary and secondary time sources located in different geographic regions using redundant authoritative time sources. Log on to NSX Manager with credentials authorized for administration, navigate and select Manage Appliance Settings >> Time Settings. Verify NTP Servers have the correct time sources. If the NSX Manager does not have primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding.
Fix Text
Change the primary and secondary time sources on the NSX Manager to time sources located in different geographic regions using redundant authoritative time sources. Log on to NSX Manager with credentials authorized for administration. Navigate and select Manage Appliance Settings >> Time Settings >> Edit. Add NTP Servers to the correct time sources. If the NSX Manager does not have primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding.
Additional Identifiers
Rule ID: SV-83807r1_rule
Vulnerability ID: V-69203
Group Title: SRG-APP-000371-NDM-000296
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001891 |
The information system compares internal information system clocks on an organization-defined frequency with an organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
AU-8 (1) |
Synchronization With Authoritative Time Source |