Check: GEN006380
      
      
        
  VMware ESX 3 Server:
  GEN006380
  
    (in version v1 r2)
  
      
      
    
  Title
The system must not use UDP for NIS/NIS+. (Cat I impact)
Discussion
Implementing NIS or NIS+ under UDP may make the system more susceptible to a Denial of Service attack and does not provide the same quality of service as TCP.
Check Content
If the system does not use NIS or NIS+, this is not applicable. Check if NIS or NIS+ is implemented using UDP. Procedure: # rpcinfo -p | grep yp | grep udp If NIS or NIS+ is implemented using UDP, this is a finding.
Fix Text
Configure the system to not use UDP for NIS and NIS+. Consult vendor documentation for the required procedure.
Additional Identifiers
Rule ID: SV-4399r2_rule
Vulnerability ID: V-4399
Group Title: GEN006380
Expert Comments
      
        
        
      
      
        
  CCIs
      
      
        
        
      
    
  | Number | Definition | 
|---|---|
| CCI-001436 | 
           The organization disables organization-defined networking protocols within the information system deemed to be nonsecure except for explicitly identified components in support of specific operational requirements.  | 
      
      
        
        
      
      
        
  Controls
      
      
        
        
      
    
  | Number | Title | 
|---|---|