Check: SRG-APP-000474-UEM-000349
Unified Endpoint Management Server SRG:
SRG-APP-000474-UEM-000349
(in versions v2 r3 through v1 r1)
Title
The UEM server must alert the system administrator when anomalies in the operation of security functions are discovered. (Cat II impact)
Discussion
If anomalies are not acted upon, security functions may fail to secure the system. Security function is defined as the hardware, software, and/or firmware of the information system responsible for enforcing the system security policy and supporting the isolation of code and data on which the protection is based. Security functionality includes, but is not limited to, establishing system accounts, configuring access authorizations (i.e., permissions, privileges), setting events to be audited, and setting intrusion detection parameters. Notifications provided by information systems include messages to local computer consoles, and/or hardware indications, such as lights. This requirement applies to applications performing security functions and the applications performing security function verification/testing. Satisfies:FAU_ALT_EXT.1.1 c.
Check Content
Verify the UEM server alerts the system administrator when anomalies in the operation of security functions are discovered. If the UEM server does not alert the system administrator when anomalies in the operation of security functions are discovered, this is a finding.
Fix Text
Configure the UEM server to alert the system administrator when anomalies in the operation of security functions are discovered.
Additional Identifiers
Rule ID: SV-234624r961737_rule
Vulnerability ID: V-234624
Group Title: SRG-APP-000474
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-002702 |
Shut the system down, restart the system, and/or initiate organization-defined alternative action(s) when anomalies in the operation of the organization-defined security functions are discovered. |
Controls
Number | Title |
---|---|
SI-6 |
Security Function Verification |