Check: TANS-SV-000029
Tanium 7.3 STIG:
TANS-SV-000029
(in versions v2 r2 through v1 r1)
Title
A Tanium connector must be configured to send log data to an external audit log reduction capable system. (Cat II impact)
Discussion
While the Tanium Server records audit log entries to the Tanium SQL database, retrieval and aggregation of log data through the Tanium console is not efficient. The Tanium Connect module allows for SIEM connectors in order to facilitate forensic data retrieval and aggregation efficiently. Consult documentation at https://docs.tanium.com/connect/connect/index.html for supported Connections.
Check Content
Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI). Log on with CAC. Click on the navigation button (hamburger menu) on the top left of the console. Click on "Connect". Review the configured Tanium Sources listed. If an "Audit Log" source does not exist, this is a finding. Select the "Audit Log" source. Select the audit connection found in the lower half of the screen. Verify the "Destination Type" is a SIEM tool. If the "Destination Type" is not a SIEM tool, this is a finding.
Fix Text
Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI). Log on with CAC. Click on the navigation button (hamburger menu) on the top left of the console. Click on "Connect". Click "Create Connection". In the Source and Destination Section, select "Audit Log" as the Event Source from the drop-down menu. In the "Destination" section, select "Socket Receiver" from the drop-down menu. Enter "Destination Name". Enter "Host". Enter "Network Protocol". Enter "Port". Consult documentation located at https://docs.tanium.com/connect/connect/index.html for reference on configuring other applicable SIEM connections.
Additional Identifiers
Rule ID: SV-234100r612749_rule
Vulnerability ID: V-234100
Group Title: SRG-APP-000358
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001851 |
The information system off-loads audit records per organization-defined frequency onto a different system or media than the system being audited. |
Controls
Number | Title |
---|---|
AU-4 (1) |
Transfer To Alternate Storage |