Check: TANS-SV-000002
Tanium 7.0 STIG:
TANS-SV-000002
(in versions v1 r2 through v1 r1)
Title
The Tanium Server console must be configured to initiate a session lock after a 15-minute period of inactivity. (Cat II impact)
Discussion
The Tanium Console, when CAC is enabled, will initiate a session lock based upon the ActivClient or other Smart Card software. By initiating the session lock, the console will be locked and not allow unauthorized access by anyone other than the original user. Although this setting does not apply when CAC is enabled, it should be explicitly disabled in the event CAC authentication is ever broken or removed.
Check Content
Using a web browser on a system that has connectivity to Tanium, access the Tanium web user interface (UI) and log on with CAC. After logging on, in the top right corner of the UI select the drop-down arrow and click on "Preferences". Verify the "Suspend console automatically if no activity detected for:" is configured to a value of "15" minutes or less. If the "Suspend console automatically if no activity detected for:" is not configured to a value of "15" minutes or less, this is a finding.
Fix Text
Using a web browser on a system that has connectivity to Tanium, access the Tanium web UI and log on with CAC. After logging on, in the top right corner of the UI select the drop-down arrow and click on "Preferences". For "Suspend console automatically if no activity detected for:", select a value of "15" minutes or less. Click "Save".
Additional Identifiers
Rule ID: SV-93365r1_rule
Vulnerability ID: V-78659
Group Title: SRG-APP-000003
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000057 |
The information system initiates a session lock after the organization-defined time period of inactivity. |
Controls
Number | Title |
---|---|
AC-11 |
Session Lock |