Check: TANS-SV-000002
Tanium 6.5 STIG:
TANS-SV-000002
(in versions v1 r3 through v1 r2)
Title
The Tanium Application Server console must be configured to initiate a session lock after a 15-minute period of inactivity. (Cat II impact)
Discussion
The Tanium Console, when CAC is enabled, will initiate a session lock based upon the ActivClient or other Smart Card software. By initiating the session lock, the console will be locked and not allow unauthorized access by anyone other than the original user. Although this setting does not apply when CAC is enabled, it should be explicitly disabled in the event CAC authentication is ever broken or removed.
Check Content
Using a web browser on a system that has connectivity to the Tanium Server, access the Tanium Server web user interface (UI) and log on with CAC. After logging in, click on "Preferences" in the top right corner of the UI. Verify the "Suspend console automatically if no activity detected for:" is configured to a value of "15" minutes or less. If the "Suspend console automatically if no activity detected for:" is not configured to a value of "15" minutes or less, this is a finding.
Fix Text
Using a web browser on a system that has connectivity to the Tanium Server, access the Tanium Server web user interface (UI) and log on with CAC. After logging in, click on "Preferences" in the top right corner of the UI. For "Suspend console automatically if no activity detected for:", select a value of 15 minutes or less. Click the “x” to close the "Preferences" box.
Additional Identifiers
Rule ID: SV-81527r1_rule
Vulnerability ID: V-67037
Group Title: SRG-APP-000003
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000057 |
Prevent further access to the system by initiating a device lock after organization-defined time period of inactivity; and/or requiring the user to initiate a device lock before leaving the system unattended. |
Controls
Number | Title |
---|---|
AC-11 |
Session Lock |