Check: SYMP-AG-000010
Symantec ProxySG ALG STIG:
SYMP-AG-000010
(in versions v1 r3 through v1 r1)
Title
If Symantec ProxySG filters externally initiated traffic, reverse proxy services must be configured. (Cat II impact)
Discussion
Automated monitoring of remote access traffic allows organizations to detect cyber attacks and also ensure ongoing compliance with remote access policies by inspecting connection activities of remote access capabilities. Remote access methods include both unencrypted and encrypted traffic (e.g., web portals, web content filter, TLS, and webmail). With inbound TLS inspection, the traffic must be inspected prior to being allowed on the enclave's web servers hosting TLS or HTTPS applications.
Check Content
The ProxySG is designed to monitor and control inbound traffic when in a reverse proxy configuration. Verify this is configured. 1. Verify with the ProxySG administrator that reverse proxy services are configured. 2. Log on to the Web Management Console. 3. Click Configuration >> Services >> Proxy Services. 4. Review each reverse proxy service identified by the administrator and Verify that all organizational services are represented by an HTTP or HTTPS proxy service in the configuration. If Symantec ProxySG filters externally initiated traffic but reverse proxy services are not configured, this is a finding.
Fix Text
Configure the ProxySG to monitor and control inbound traffic by configuring reverse proxy services. This provides SSL proxy in reverse proxy mode. 1. Log on to the Web Management Console. 2. Click Configuration >> Services >> Proxy Services. 3. Click "New Service". 4. Enter information into the various service boxes in accordance with site architecture, operational requirements, and SSP requirements for which web servers are to be monitored and controlled.
Additional Identifiers
Rule ID: SV-104171r1_rule
Vulnerability ID: V-94217
Group Title: SRG-NET-000061-ALG-000009
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000067 |
The information system monitors remote access methods. |
Controls
Number | Title |
---|---|
AC-17 (1) |
Automated Monitoring / Control |