Check: GEN007900
SUSE Linux Enterprise Server v11 for System z STIG:
GEN007900
(in versions v1 r12 through v1 r9)
Title
The system must use an appropriate reverse-path filter for IPv6 network traffic, if the system uses IPv6. (Cat II impact)
Discussion
Reverse-path filtering provides protection against spoofed source addresses by causing the system to discard packets with source addresses for which the system has no route or if the route does not point towards the interface on which the packet arrived. Depending on the role of the system, reverse-path filtering may cause legitimate traffic to be discarded and, therefore, should be used with a more permissive mode or filter, or not at all. Whenever possible, reverse-path filtering should be used.
Check Content
Reverse Path filtering for IPv6 is not implemented in SLES.
Fix Text
If the system uses IPv6 use an appropriate reverse-path filter for IPV6 network traffic.
Additional Identifiers
Rule ID: SV-46104r1_rule
Vulnerability ID: V-22552
Group Title: GEN007900
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001551 |
The organization defines approved authorizations for controlling the flow of information between interconnected systems. |
Controls
Number | Title |
---|---|
AC-4 |
Information Flow Enforcement |