Check: RINP-DM-000048
Riverbed NetProfiler STIG:
RINP-DM-000048
(in versions v2 r1 through v1 r1)
Title
The Riverbed NetProfiler must be configured to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC). (Cat II impact)
Discussion
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
Check Content
Go to Administration >> General Settings. Under "Time Configuration", verify the Time Zone is set to "UTC". If the Time Zone is not "UTC", this is a finding.
Fix Text
Go to Administration >> General Settings. Under "Time Configuration", configure the Time Zone to "UTC".
Additional Identifiers
Rule ID: SV-256086r961443_rule
Vulnerability ID: V-256086
Group Title: SRG-APP-000374-NDM-000299
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001890 |
Record time stamps for audit records that use Coordinated Universal Time, have a fixed local time offset from Coordinated Universal Time, or that include the local time offset as part of the time stamp. |
Controls
Number | Title |
---|---|
AU-8 |
Time Stamps |