Check: DTOO346
Microsoft Project 2013 STIG:
DTOO346
(in versions v1 r4 through v1 r2)
Title
Untrusted intranet zone access to Project servers must not be allowed. (Cat II impact)
Discussion
Enabling this setting allows users to access Project server websites and workspaces outside of the trusted Internet zone. As a result, malicious code could become active on user computers or the network to gain access to sensitive data. In this situation, the site could attempt to capture personal information, such as passwords and user names.
Check Content
Verify the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2013 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" is set to "Disabled". Procedure: Use the Windows Registry Editor to navigate to the following key: HKCU\Software\Policies\Microsoft\Office\15.0\ms project\security Criteria: If the value TrustWSS is REG_DWORD = 0, this is not a finding.
Fix Text
Set the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2013 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" to "Disabled".
Additional Identifiers
Rule ID: SV-53234r1_rule
Vulnerability ID: V-40892
Group Title: DTOO346 - Untrusted intranet zone
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001170 |
The information system prevents the automatic execution of mobile code in organization-defined software applications. |
Controls
Number | Title |
---|---|
SC-18 (4) |
Prevent Automatic Execution |