Check: KVM04.003.00
KVM:
KVM04.003.00
(in version v2 r6)
Title
The A/B switch must be physically protected in accordance with the requirements of the highest classification of any IS connected to the A/B switch. (Cat I impact)
Discussion
If the A/B switch is not located in an area that has the same physical security as required by the IS of the highest classification level, this can lead to a compromise of sensitive data. The ISSO or SA will ensure the A/B switch is physically protected in accordance with the requirements of the highest classification for any IS connected to the A/B switch.
Check Content
The reviewer will view the A/B switch to verify it is physically protected in accordance with the requirements of the highest classification of any IS connected to the A/B switch. If it is in the same location as the ISs connected then it is adequately protected. If the switch is not physically protected in accordance with the classification level of the highest attached IS, this is a finding.
Fix Text
Move the A/B switch to a location where it is protected in the same manner as required by the IS of the highest classification level the A/B switch is attached.
Additional Identifiers
Rule ID: SV-6923r2_rule
Vulnerability ID: V-6720
Group Title:
Expert Comments
CCIs
Number | Definition |
---|---|
No CCIs are assigned to this check |
Controls
Number | Title |
---|---|
No controls are assigned to this check |