Check: WSDP-NM-000054
IBM DataPower Network Device Management STIG:
WSDP-NM-000054
(in versions v1 r2 through v1 r1)
Title
The DataPower Gateway must prohibit password reuse for a minimum of five generations. (Cat II impact)
Discussion
Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. To meet password policy requirements, passwords need to be changed at specific policy-based intervals. If the network device allows the user to consecutively reuse their password when that password has exceeded its defined lifetime, the end result is a password that is not changed as per policy requirements.
Check Content
Search Bar “Administration” >> Access >> RBM Settings >> Password Policy. If Control reuse is Off, this is a finding.
Fix Text
Search Bar “Administration” >> Access >> RBM Settings >> Password Policy. Set Control reuse to On, set Reuse history to at least 5.
Additional Identifiers
Rule ID: SV-79583r1_rule
Vulnerability ID: V-65093
Group Title: SRG-APP-000165-NDM-000253
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000200 |
The information system prohibits password reuse for the organization-defined number of generations. |
Controls
Number | Title |
---|---|
IA-5 (1) |
Password-Based Authentication |