Check: AIX7-00-001053
IBM AIX 7.x STIG:
AIX7-00-001053
(in versions v3 r1 through v1 r1)
Title
AIX must provide time synchronization applications that can synchronize the system clock to external time sources at least every 24 hours. (Cat II impact)
Discussion
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144
Check Content
Check if time synchronization application "ntpd" is running using the command: # lssrc -s xntpd Subsystem Group PID Status xntpd tcpip 4784536 active If "ntpd" is showing "inoperative", this is a finding. Check that "ntp" server is configured using command: # grep server /etc/ntp.conf server 10.110.20.10 If the command returns no output, this is a finding. Check the poll interval is less than 24 hours using command: # grep maxpoll /etc/ntp.conf maxpoll=16 If "maxpoll" is set to larger than "16" (2^16 seconds ~= 18hr), this is a finding.
Fix Text
Edit /etc/ntp.conf Configure ntp server by adding the following line: server server_ipaddr Set maxpoll to <value> <=16 by adding the maxpoll <value>. Restart the ntp daemon. # stopsrc -s xntpd # startsrc -s xntpd
Additional Identifiers
Rule ID: SV-215208r1009533_rule
Vulnerability ID: V-215208
Group Title: SRG-OS-000355-GPOS-00143
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001891 |
The information system compares internal information system clocks on an organization-defined frequency with an organization-defined authoritative time source. |
CCI-002046 |
The information system synchronizes the internal system clocks to the authoritative time source when the time difference is greater than the organization-defined time period. |
CCI-004923 |
Compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. |
CCI-004926 |
Synchronize the internal system clocks to the authoritative time source when the time difference is greater than organization-defined time period. |
Controls
Number | Title |
---|---|
AU-8(1) |
Synchronization with Authoritative Time Source |