Check: HYCU-ND-000440
HYCU Protege STIG:
HYCU-ND-000440
(in version v1 r1)
Title
The HYCU virtual appliance must be configured to synchronize internal information system clocks using redundant authoritative time sources. (Cat II impact)
Discussion
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must use an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source. Satisfies: SRG-APP-000920-NDM-000320, SRG-APP-000925-NDM-000330
Check Content
Verify the "chronyd" service is up and running, execute the following command: systemctl status chronyd If service is not active (running), this is a finding. To verify chronyd has synced time and can reach the servers execute the following command: chronyc sources If there are not two NTP servers listed, this is a finding. If the "Reach" value is lower than "377" for the source with S column marked with "*" this is a finding.
Fix Text
Start the time synchronization by logging on to the HYCU console and executing the following command: sudo systemctl restart chronyd Additional assistance can be found at: https://support.hycu.com/hc/en-us/articles/115005424345-HYCU-system-time
Additional Identifiers
Rule ID: SV-268216r1038348_rule
Vulnerability ID: V-268216
Group Title: SRG-APP-000920-NDM-000320
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-004922 |
Synchronize system clocks within and between systems or system components. |
CCI-004923 |
Compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
No controls are assigned to this check |