Check: HONW-09-000400
Honeywell Android 9.x COPE STIG:
HONW-09-000400
(in versions v1 r2 through v1 r1)
Title
The Honeywell Mobility Edge Android Pie device must be configured to lock the display after 15 minutes (or less) of inactivity. (Cat II impact)
Discussion
The screen lock timeout must be set to a value that helps protect the device from unauthorized access. Having a too-long timeout would increase the window of opportunity for adversaries who gain physical access to the mobile device through loss, theft, etc. Such devices are much more likely to be in an unlocked state when acquired by an adversary, thus granting immediate access to the data on the mobile device. The maximum timeout period of 15 minutes has been selected to balance functionality and security; shorter timeout periods may be appropriate depending on the risks posed to the mobile device. SFR ID: FMT_SMF_EXT.1.1 #2b
Check Content
Review Honeywell Android device configuration settings to determine if the mobile device has the screen lock timeout set to 15 minutes or less. This validation procedure is performed on both the MDM Administration console and the Android Pie device. On the MDM console: 1. Open passcode requirements. 2. Open device passcode section. 3. Ensure "Device Lock Timeout" to any number between 1 and 15. On the Honeywell Android Pie device: 1. Open settings >> Security & location. 2. Click the "gear" icon next to "Screen lock". 3. Ensure "Automatically lock" is set to between 0 and 15 minutes. If the MDM console device policy is not set to 15 minutes or less for the screen lock timeout or on the Honeywell Android Pie device, the device policy is not set to 15 minutes or less for the screen lock timeout, this is a finding.
Fix Text
Configure the Honeywell Android device to lock the device display after 15 minutes (or less) of inactivity. On the MDM console: 1. Open password requirements. 2. Open device password section. 3. Set "Device Lock Timeout" to any number between 1 and 15.
Additional Identifiers
Rule ID: SV-235065r626531_rule
Vulnerability ID: V-235065
Group Title: PP-MDF-301040
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000057 |
The information system initiates a session lock after the organization-defined time period of inactivity. |
Controls
Number | Title |
---|---|
AC-11 |
Session Lock |