Check: GEN000242
HP-UX 11.31 STIG:
GEN000242
(in versions v1 r19 through v1 r13)
Title
The system must use at least two time sources for clock synchronization. (Cat II impact)
Discussion
A synchronized system clock is critical for the enforcement of time-based policies and the correlation of logs and audit records with other systems. For redundancy, two time sources are required so synchronization continues to function if one source fails. If the system is completely isolated (no connections to networks or other systems), time synchronization is not required as no correlation of events or operation of time-dependent protocols between systems will be necessary. If the system is completely isolated, this requirement is not applicable. NOTE: For the Network Time Protocol (NTP), the requirement is two servers, but it is recommended to configure at least four distinct time servers which allow NTP to effectively exclude a time source that is not consistent with the others. The system's local clock must be excluded from the count of time sources.
Check Content
Check the system for a running NTP daemon. # ps -ef | grep ntp Verify the auto-startup of (x)ntpd in /etc/rc.config.d/netdaemons. # cat /etc/rc.config.d/netdaemons | grep -v "^#" | grep -i "XNTPD=1" Verify at least two external NTP servers are listed in the /etc/ntp.conf file. # cat /etc/ntp.conf | grep -v "^#" | grep -i server | \ egrep -v "127.127.1.1|127.127.1.0" If xntpd is not invoked with at least two external NTP servers listed (127.127.1.0 or 127.127.1.1 are local clock references and therefore not allowed), this is a finding.
Fix Text
If auto-starting (x)ntpd, add (when necessary) the correct number of (at least two) external servers to the /etc/ntp.conf file. If using ntpdate, add additional NTP servers (at least two are required) to the cron job running ntpdate.
Additional Identifiers
Rule ID: SV-38297r1_rule
Vulnerability ID: V-22291
Group Title: GEN000242
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000160 |
The information system synchronizes internal information system clocks on an organization-defined frequency with an organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
No controls are assigned to this check |