Check: GOOG-09-010200
Google Android 9.x STIG:
GOOG-09-010200
(in versions v2 r1 through v1 r1)
Title
Google Android Pie must be configured to disallow configuration of date and time. (Cat II impact)
Discussion
Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Periodically synchronizing internal clocks with an authoritative time source is necessary to correctly correlate the timing of events that occur across the enterprise. The three authoritative time sources for Google Android Pie are an authoritative time server that is synchronized with redundant United States Naval Observatory (USNO) time servers as designated for the appropriate DoD network (NIPRNet or SIPRNet), or the Global Positioning System (GPS), or the wireless carrier. Time stamps generated by the audit system in Google Android Pie must include both date and time. The time may be expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. SFR ID: FMT_SMF_EXT.1.1 #47
Check Content
Review the Google Android Pie Work Profile configuration settings to confirm that autofill services are disabled. This procedure is performed on both the MDM Administration console and the Google Android Pie device. On the MDM console, verify that "Set auto (network) time required" to on". On the Google Android Pie device, do the following: 1. Open Settings. 2. Tap "System". 3. Tap "Date & times". 4. Verify that "Automatic date & time" is grayed out. If on the MDM console "Set auto (network) time required" to on", or on the Google Android Pie device "Automatic date & time" is grayed out, this is a finding.
Fix Text
Configure Google Android Pie Work Profile to set auto network time. On the MDM console, in the Android user restrictions section, select "Set auto (network) time required" to on".
Additional Identifiers
Rule ID: SV-106467r1_rule
Vulnerability ID: V-97363
Group Title: PP-MDF-991000
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000366 |
The organization implements the security configuration settings. |
Controls
Number | Title |
---|---|
CM-6 |
Configuration Settings |