Check: GOOG-09-000300
Google Android 9.x STIG:
GOOG-09-000300
(in versions v2 r1 through v1 r1)
Title
The Google Android Pie must be configured to enable a screen-lock policy that will lock the display after a period of inactivity. (Cat II impact)
Discussion
The screen-lock timeout helps protect the device from unauthorized access. Devices without a screen-lock timeout provide an opportunity for adversaries who gain physical access to the mobile device through loss, theft, etc. Such devices are much more likely to be in an unlocked state when acquired by an adversary, thus granting immediate access to the data on the mobile device and possibly access to DoD networks. SFR ID: FMT_SMF_EXT.1.1 #2a
Check Content
Review Google Android device configuration settings to determine if the mobile device is enforcing a screen-lock policy that will lock the display after a period of inactivity. This validation procedure is performed on both the MDM Administration Console and the Android Pie device. On the MDM console, do the following: 1. Open password requirements 2. Open device password section 3. Ensure "Device Lock Timeout" is set to any number desired. Units are in Minutes. On the Android Pie device, do the following: 1. Open settings >> Security & location 2. Click the "gear" icon next to "Screen lock" 3. Ensure "Automatically lock" is set at a required time If the MDM console device policy is not set to enable a screen-lock policy that will lock the display after a period of inactivity or on the Android Pie device, the device policy is not set to enable a screen-lock policy that will lock the display after a period of inactivity, this is a finding.
Fix Text
Configure the Google Android device to enable a screen-lock policy that will lock the display after a period of inactivity. On the MDM Console: 1. Open password requirements. 2. Open device password section. 3. Set "Device Lock Timeout" to any number desired. Units are in Minutes.
Additional Identifiers
Rule ID: SV-106413r1_rule
Vulnerability ID: V-97309
Group Title: PP-MDF-301030
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000057 |
The information system initiates a session lock after the organization-defined time period of inactivity. |
Controls
Number | Title |
---|---|
AC-11 |
Session Lock |