Check: DBNW-DM-000029
DBN-6300 NDM STIG:
DBNW-DM-000029
(in version v1 r1)
Title
The DBN-6300 must produce audit records containing information to establish where the events occurred. (Cat III impact)
Discussion
In order to compile an accurate risk assessment and provide forensic analysis, it is essential for security personnel to know where events occurred, such as device hardware components, device software modules, session identifiers, filenames, host names, and functionality. Location of events includes hardware components, device software module, session identifiers, filenames, host names, and functionality.
Check Content
Verify the DBN-6300 is connected to the syslog server. Navigate to Settings >> Advanced >> Syslog. Verify that the syslog services are set to "on", the syslog server information is valid, and the syslog server has connected. Navigate to Settings >> Advanced >> Audit Log. Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console. Following this verification, process an auditable action. Confirm the presence of a syslog message on the syslog server containing information to establish where the event occurred. If the DBN-6300 is not connected to the syslog server, or if the syslog server is connected but the message for the event does not contain information to establish where the event occurred, this is a finding.
Fix Text
Configure the DBN-6300 to be connected to the syslog server. Also configure the DBN-6300 to include audit records in the syslog message feed. Navigate to Settings >> Advanced >> Syslog. Enter the syslog connection information (port and IP address) and push the "enabled" button for both "TCP" and "enable". Navigate to Settings >> Advanced >> Audit Log. Verify that the Audit Syslog, "Use System Syslog" button is set to "Yes" and the Audit Configuration Categories are all checked for Audit Log, Syslog, and Audit Console. If the "Use System Syslog" button is not set to "Yes", press the "Yes" button. Click on "Commit".
Additional Identifiers
Rule ID: SV-91633r1_rule
Vulnerability ID: V-76937
Group Title: SRG-APP-000097-NDM-000227
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000132 |
The information system generates audit records containing information that establishes where the event occurred. |
Controls
Number | Title |
---|---|
AU-3 |
Content Of Audit Records |