Check: CISC-RT-000670
Cisco IOS XE Switch RTR STIG:
CISC-RT-000670
(in versions v2 r5 through v1 r0.1)
Title
The Cisco PE switch providing MPLS Virtual Private Wire Service (VPWS) must be configured to have the appropriate virtual circuit identification (VC ID) for each attachment circuit. (Cat I impact)
Discussion
VPWS is an L2VPN technology that provides a virtual circuit between two PE switches to forward Layer 2 frames between two customer-edge switches or switches through an MPLS-enabled IP core. The ingress PE switch (virtual circuit head-end) encapsulates Ethernet frames inside MPLS packets using label stacking and forwards them across the MPLS network to the egress PE switch (virtual circuit tail-end). During a virtual circuit setup, the PE switches exchange VC label bindings for the specified VC ID. The VC ID specifies a pseudowire associated with an ingress and egress PE switch and the customer-facing attachment circuits. To guarantee that all frames are forwarded onto the correct pseudowire and to the correct customer and attachment circuits, it is imperative that the correct VC ID is configured for each attachment circuit.
Check Content
Verify that the correct and unique VCID has been configured for the appropriate attachment circuit. In the example below, GigabitEthernet0/1 is the CE-facing interface that is configured for VPWS with the VCID of 55. interface GigabitEthernet0/1 xconnect x.2.2.12 55 encapsulation mpls If the correct VC ID has not been configured on both switches, this is a finding.
Fix Text
Assign globally unique VC IDs for each virtual circuit and configure the attachment circuits with the appropriate VC ID.
Additional Identifiers
Rule ID: SV-221041r622190_rule
Vulnerability ID: V-221041
Group Title: SRG-NET-000512-RTR-000008