Check: SRG-APP-000374-AU-000290
Central Log Server SRG:
SRG-APP-000374-AU-000290
(in versions v3 r2 through v1 r0.1)
Title
Upon receipt of the log record from hosts and devices, the Central Log Server must be configured to record time stamps of the time of receipt that can be mapped to Coordinated Universal Time (UTC). (Cat III impact)
Discussion
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
Check Content
Examine the log records stored on the events server. Verify the Central Log Server records time stamps of the time the record was received from the host or device. Verify the time stamp is mapped to UTC. If the Central Log Server is not configured to record time stamps of the time the record was received or the time stamp is not mapped to UTC, this is a finding.
Fix Text
Configure the Central Log Server to record time stamps of the time the record was received from the host or device. Verify the time stamp is mapped to UTC.
Additional Identifiers
Rule ID: SV-206504r961443_rule
Vulnerability ID: V-206504
Group Title: SRG-APP-000374
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001890 |
Record time stamps for audit records that use Coordinated Universal Time, have a fixed local time offset from Coordinated Universal Time, or that include the local time offset as part of the time stamp. |
Controls
Number | Title |
---|---|
AU-8 |
Time Stamps |