Check: AMLS-NM-000380
Arista MLS DCS-7000 Series NDM STIG:
AMLS-NM-000380
(in versions v1 r3 through v1 r2)
Title
The Arista Multilayer Switch must generate audit records when concurrent logons from different workstations occur. (Cat II impact)
Discussion
Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the information system (e.g., module or policy filter).
Check Content
Determine if the network device generates audit records when concurrent logons from different workstations occur. If the network device does not generate audit records when concurrent logons from different workstations occur, this is a finding. Verify by reviewing log files to show concurrent logons to the system via the "Show Logging" command.
Fix Text
Configure the network device to generate audit records when concurrent logons from different workstations occur. Enable logging level 6 to ensure this event is captured. Switch(config)#logging trap 6 switch(config)#logging level all 6
Additional Identifiers
Rule ID: SV-75335r1_rule
Vulnerability ID: V-60877
Group Title: SRG-APP-000506-NDM-000323
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000172 |
The information system generates audit records for the events defined in AU-2 d. with the content defined in AU-3. |
Controls
Number | Title |
---|---|
AU-12 |
Audit Generation |