Check: SRG-NET-000365-ALG-000123
Application Layer Gateway SRG:
SRG-NET-000365-ALG-000123
(in versions v2 r2 through v1 r2)
Title
The ALG must fail securely in the event of an operational failure. (Cat II impact)
Discussion
If a boundary protection device fails in an unsecure manner (open), information external to the boundary protection device may enter, or the device may permit unauthorized information release. Secure failure ensures when a boundary control device fails, all traffic will be subsequently denied. Fail secure is a condition achieved by employing information system mechanisms to ensure in the event of operational failures of boundary protection devices at managed interfaces (e.g., routers, firewalls, guards, and application gateways residing on protected subnetworks commonly referred to as demilitarized zones), information systems do not enter into unsecure states where intended security properties no longer hold.
Check Content
Verify the ALG fails securely in the event of an operational failure. If the ALG does not fail securely in the event of an operational failure, this is a finding.
Fix Text
Configure the ALG to fail securely in the event of an operational failure.
Additional Identifiers
Rule ID: SV-205009r396402_rule
Vulnerability ID: V-205009
Group Title: SRG-NET-000365
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001126 |
Prevent systems from entering unsecure states in the event of an operational failure of a boundary protection device. |
Controls
Number | Title |
---|---|
SC-7(18) |
Fail Secure |