Check: AIOS-11-005400
Apple iOS 11 STIG:
AIOS-11-005400
(in versions v1 r4 through v1 r1)
Title
Apple iOS must disable automatic transfer of diagnostic data to an external device other than an MDM service with which the device has enrolled. (Cat III impact)
Discussion
Many software systems automatically send diagnostic data to the manufacturer or a third party. This data enables the developers to understand real-world field behavior and improve the product based on that information. Unfortunately, it can also reveal information about what DoD users are doing with the systems and what causes them to fail. An adversary embedded within the software development team or elsewhere could use the information acquired to breach mobile operating system security. Disabling automatic transfer of such information mitigates this risk. SFR ID: FMT_SMF_EXT.1.1#47a
Check Content
Review configuration settings to confirm "Allow sending diagnostic and usage data to Apple" is disabled. This check procedure is performed on both the iOS management tool and the iOS device. Note: If an organization has multiple configuration profiles, the check procedure must be performed on the relevant configuration profiles applicable to the scope of the review. In the iOS management tool, verify "Allow sending diagnostic and usage data to Apple" is unchecked. Alternatively, verify the text "<key>allowDiagnosticSubmission</key><false/>" appears in the configuration profile (.mobileconfig file). On the Apple iOS device: 1. Open the Settings app. 2. Tap "General". 3. Tap "Profiles & Device Management". 4. Tap the Configuration Profile from the iOS management tool containing the management policy. 5. Verify "Diagnostics submission not allowed" Note: This setting also disables "Share With App Developers". If "Allow sending diagnostic and usage data to Apple" is checked in the iOS management tool, "<key>allowDiagnosticSubmission</key><true/>" appears in the configuration profile, or the restrictions policy on the Apple iOS device from the Apple iOS management tool does not list "Automatically Send", this is a finding.
Fix Text
Install a configuration profile to disable sending diagnostic data to an organization other than DoD.
Additional Identifiers
Rule ID: SV-93105r1_rule
Vulnerability ID: V-78399
Group Title: PP-MDF-301270
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000381 |
The organization configures the information system to provide only essential capabilities. |
Controls
Number | Title |
---|---|
CM-7 |
Least Functionality |