Check: CF11-02-000079
Adobe ColdFusion 11 STIG:
CF11-02-000079
(in versions v2 r1 through v1 r2)
Title
ColdFusion logs must, at a minimum, be transferred simultaneously for interconnected systems and transferred weekly for standalone systems. (Cat II impact)
Discussion
Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Protecting log data is important during a forensic investigation to ensure investigators can track and understand what may have occurred. ColdFusion does not offer an automated mechanism to off-load logs, but ColdFusion does have the capability to create archive log files. By using the archive capability, off-loading can be set up using a weekly scheduled task for standalone systems. For interconnected systems, applications such as syslog on Linux can be used to off-load data simultaneously.
Check Content
Interview the administrator to determine whether or not ColdFusion logs are transferred to another system weekly for standalone systems and simultaneously for interconnected systems. If the logs are not transferred weekly for standalone systems and simultaneously for interconnected systems, this is a finding.
Fix Text
Implement a strategy that transfers logs weekly for standalone systems and simultaneously for interconnected systems.
Additional Identifiers
Rule ID: SV-237159r641572_rule
Vulnerability ID: V-237159
Group Title: SRG-APP-000515-AS-000203
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001851 |
Transfer audit logs per organization-defined frequency to a different system, system component, or media than the system or system component conducting the logging. |
Controls
Number | Title |
---|---|
AU-4(1) |
Transfer to Alternate Storage |