CCI-000961
Provide an alternate power supply for the system that is activated manually or automatically and that can maintain minimally required operational capability in the event of an extended loss of the primary power source.
Draft
PE-11(1)
CCI-000962
The organization provides a long-term alternate power supply for the information system that is self-contained and not reliant on external power generation.
Draft
CCI-000963
Employ and maintains automatic emergency lighting for the information system that activates in the event of a power outage or disruption and that covers emergency exits and evacuation routes within the facility.
Draft
PE-12
CCI-000964
The organization provides emergency lighting for all areas within the facility supporting essential missions and business functions.
Draft
CCI-000965
Employ and maintain fire detection and suppression systems that are supported by an independent energy source.
Draft
PE-13
CCI-000966
The organization employs fire detection devices/systems for the information system that activate automatically and notify the organization and emergency responders in the event of a fire.
Draft
CCI-000967
The organization employs fire suppression devices/systems for the information system that provide automatic notification of any activation to the organization and emergency responders.
Draft
CCI-000968
Employ an automatic fire suppression capability for the system when the facility is not staffed on a continuous basis.
Draft
PE-13(3)
CCI-000969
The organization ensures that the facility undergoes, on an organization-defined frequency, fire marshal inspections and promptly resolves identified deficiencies.
Draft
CCI-000970
The organization defines a frequency for fire marshal inspections.
Draft
CCI-000971
Maintain temperature; humidity; pressure; radiation; and/or organization-defined environmental control levels within the facility where the system resides at organization-defined acceptable levels.
Draft
PE-14
CCI-000972
Defines acceptable temperature, humidity, pressure, radiation, and/or organization-defined environmental control levels to be maintained within the facility where the system resides.
Draft
PE-14
CCI-000973
Monitor environmental control levels in accordance with organization-defined frequency.
Draft
PE-14
CCI-000974
Defines a frequency for monitoring environmental control levels.
Draft
PE-14
CCI-000975
Employ organization-defined automatic environmental controls in the facility to prevent fluctuations potentially harmful to the system.
Draft
PE-14(1)
CCI-000976
Employ environmental control monitoring that provides an alarm or notification of changes potentially harmful to personnel or equipment to organization-defined personnel or roles.
Draft
PE-14(2)
CCI-000977
Protect the system from damage resulting from water leakage by providing master shutoff or isolation valves that are accessible.
Draft
PE-15
CCI-000978
Protect the system from damage resulting from water leakage by providing master shutoff or isolation valves that are working properly.
Draft
PE-15
CCI-000979
Key personnel have knowledge of the master water shutoff or isolation valves.
Draft
PE-15
CCI-000980
The organization employs mechanisms that, without the need for manual intervention, protect the information system from water damage in the event of a water leak.
Draft
CCI-000981
Authorize organization-defined types of system components entering and exiting the facility.
Draft
PE-16
CCI-000982
The organization monitors organization-defined types of information system components entering and exiting the facility.
Draft
PE-16
CCI-000983
Control organization-defined types of system components entering and exiting the facility.
Draft
PE-16
CCI-000984
Maintain records of system components.
Draft
PE-16
CCI-000985
Employ organization-defined controls at alternate work sites.
Draft
PE-17
CCI-000986
The organization defines management, operational, and technical information system security controls to be employed at alternate work sites.
Draft
CCI-000987
Assess as feasible, the effectiveness of controls at alternate work sites.
Draft
PE-17
CCI-000988
Provide a means for employees to communicate with information security personnel in case of incidents.
Draft
PE-17
CCI-000989
Position system components within the facility to minimize potential damage from organization-defined physical and environmental hazards.
Draft
PE-18
CCI-000990
The organization positions information system components within the facility to minimize potential damage from environmental hazards.