z/OS NetView for ACF2 STIG Version Comparison
z/OS NetView for ACF2 Security Technical Implementation Guide
Comparison
There are 1 differences between versions v6 r8 (July 22, 2016) (the "left" version) and v6 r9 (Nov. 23, 2022) (the "right" version).
Check ZNETA020 was changed between these two versions. Green, underlined text was added, red, struck-out text was removed.
The regular view of the left check and right check may be easier to read.
Text Differences
Title
NetView resources must be properly defined and protected.
Check Content
Refer to the following report produced by the ACF2 Data Collection and Data Set and Resource Data Collection: - SENSITVE.RPT(ZNET0020) - ACF2CMDS.RPT(RESOURCE) – Collection: - SENSITVE.RPT(ZNET0020) - ACF2CMDS.RPT(RESOURCE) - Alternate report Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZNET0020) When Collection: - PDI(ZNET0020) When SECOPTS.OPERSEC=SAFPW is specified in ZNET0040, this is not applicable. Ensure that all NetView resources and/or generic equivalents are properly protected according to the requirements specified in the NetView Resources table in the z/OS STIG Addendum. If the following guidance is true, this is not a finding. ___ The finding. ___ The ACF2 resources are defined with a default access of PREVENT. ___ The PREVENT. ___ The ACF2 resource access authorizations restrict access to the appropriate personnel.
Discussion
NetView can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control access to product resources could result in the compromise of the operating system environment, and compromise the confidentiality of customer data. Many utilities assign resource controls that can be granted to system programmers only in greater than read authority. Resources are also granted to certain non systems personnel with read only authority.
Fix
The IAO ISSO will work with the systems programmer to verify that the following are properly specified in the ACP. (Note: The resource type, resources, and/or resource prefixes identified below are examples of a possible installation. The actual resource type, resources, and/or resource prefixes are determined when the product is actually installed on a system through the product’s product's installation guide and can be site specific.) When SECOPTS.OPERSEC=SAFPW is specified in ZNET0040, this is not applicable. This can be bypassed. Ensure that all NetView resources and/or generic equivalents are properly protected according to the requirements specified in the NetView Resources table in the z/OS STIG Addendum. Additional details can be obtained in the IBM Tivoli NetView for z/OS Security Reference. Use the NetView Resources table in the z/OS STIG Addendum. This table lists the resources and access requirements for NetView, ensure the following guidelines are followed: The ACF2 resources are defined with a default access of PREVENT. The ACF2 resource access authorizations restrict access to the appropriate personnel. The following commands are provided as a sample for implementing resource controls: $KEY(netid) TYPE(typecode) luname.ADDCMD.- UID(syspaudt) ALLOW - UID(*) PREVENT