Check: ZMVZA030
z/OS BMC MAINVIEW for z/OS for ACF2 STIG:
ZMVZA030
(in versions v6 r10 through v6 r8)
Title
BMC Mainview for z/OS Started Task name must be properly identified and/or defined to the system ACP. (Cat II impact)
Discussion
BMC Mainview for z/OS requires a started task that will be restricted to certain resources, datasets and other system functions. By defining the started task as a userid to the system ACP, It allows the ACP to control the access and authorized users that require these capabilities. Failure to properly control these capabilities, could compromise of the operating system environment, ACP, and customer data.
Check Content
Refer to the following report produced by the ACF2 Data Collection: - ACF2CMDS.RPT(ATTSTC) Insure that the logonids(s) for the BMC Mainview for z/OS started task(s) includes the following: STC NO-SMC
Fix Text
Ensure that a product's Started Task(s) is properly identified and/or defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. Example: SET LID INSERT MV$CAS STC NO-SMC INSERT MV$PAS STC NO-SMC INSERT MV$MVS STC NO-SMC
Additional Identifiers
Rule ID: SV-224253r518970_rule
Vulnerability ID: V-224253
Group Title: SRG-OS-000104
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000764 |
The information system uniquely identifies and authenticates organizational users (or processes acting on behalf of organizational users). |
Controls
Number | Title |
---|---|
IA-2 |
Identification And Authentication (Organizational Users) |