Check: WN12-SO-000049
Microsoft Windows Server 2012/2012 R2 Member Server STIG:
WN12-SO-000049
(in versions v3 r7 through v2 r7)
Title
The system must generate an audit event when the audit log reaches a percentage of full threshold. (Cat III impact)
Discussion
When the audit log reaches a given percent full, an audit event is written to the security log. It is recorded as a successful audit event under the category of System. This option may be especially useful if the audit logs are set to be cleared manually.
Check Content
If the system is configured to write to an audit server, or is configured to automatically archive full logs, this is NA. If the following registry value does not exist or is not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \System\CurrentControlSet\Services\Eventlog\Security\ Value Name: WarningLevel Value Type: REG_DWORD Value: 90 (or less)
Fix Text
Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> "MSS: (WarningLevel) Percentage threshold for the security event log at which the system will generate a warning" to "90" or less. (See "Updating the Windows Security Options File" in the STIG Overview document if MSS settings are not visible in the system's policy tools.)
Additional Identifiers
Rule ID: SV-225490r852259_rule
Vulnerability ID: V-225490
Group Title: SRG-OS-000046-GPOS-00022
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000139 |
The information system alerts designated organization-defined personnel or roles in the event of an audit processing failure. |
CCI-001855 |
The information system provides a warning to organization-defined personnel, roles, and/or locations within an organization-defined time period when allocated audit record storage volume reaches an organization-defined percentage of repository maximum audit record storage capacity. |
CCI-001858 |
The information system provides a real-time alert in an organization-defined real-time period to organization-defined personnel, roles, and/or locations when organization-defined audit failure events requiring real-time alerts occur. |