Check: SRG-APP-000375-WSR-000171
Web Server SRG:
SRG-APP-000375-WSR-000171
(in versions v4 r2 through v2 r2)
Title
The web server must record time stamps for log records to a minimum granularity of one second. (Cat II impact)
Discussion
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the web server include date and time and must be to a granularity of one second.
Check Content
Review the web server documentation and configuration to determine if log records are time stamped to a minimum granularity of one second. Have a user generate a logable event and review the log data to determine if the web server is configured correctly. If the log data does not contain a time stamp to a minimum granularity of one second, this is a finding.
Fix Text
Configure the web server to record log events with a time stamp to a granularity of one second.
Additional Identifiers
Rule ID: SV-206426r961446_rule
Vulnerability ID: V-206426
Group Title: SRG-APP-000375
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001889 |
Record time stamps for audit records that meet organization-defined granularity of time measurement. |
Controls
Number | Title |
---|---|
AU-8 |
Time Stamps |