Check: SRG-APP-000925-WSR-000330
Web Server SRG:
SRG-APP-000925-WSR-000330
(in versions v4 r2 through v4 r1)
Title
The web server must compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. (Cat II impact)
Discussion
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.
Check Content
Verify the web server is configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. If the web server is not configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source, this is a finding.
Fix Text
Configure the web server to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.
Additional Identifiers
Rule ID: SV-264359r984422_rule
Vulnerability ID: V-264359
Group Title: SRG-APP-000925
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-004923 |
Compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
No controls are assigned to this check |