Check: ESXI-65-000050
VMware vSphere 6.5 ESXi STIG:
ESXI-65-000050
(in versions v2 r4 through v1 r1)
Title
The ESXi host must protect the confidentiality and integrity of transmitted information by protecting IP based management traffic. (Cat II impact)
Discussion
Virtual machines might share virtual switches and VLANs with the IP-based storage configurations. IP-based storage includes vSAN, iSCSI and NFS. This configuration might expose IP-based storage traffic to unauthorized virtual machine users. IP-based storage frequently is not encrypted. It can be viewed by anyone with access to this network. To restrict unauthorized users from viewing the IP-based storage traffic, the IP-based storage network must be logically separated from the production traffic. Configuring the IP-based storage adaptors on separate VLANs or network segments from other VMkernels and Virtual Machines will limit unauthorized users from viewing the traffic.
Check Content
IP-Based storage (iSCSI, NFS, vSAN) VMkernel port groups must be in a dedicated VLAN that can be on a common standard or distributed virtual switch that is logically separated from other traffic types. The check for this will be unique per environment. From the vSphere Web Client select the ESXi Host and go to Configure >> Networking >> VMkernel adapters and review the VLANs associated with any IP-Based storage VMkernels and verify they are dedicated for that purpose and are logically separated from other functions. If any IP-Based storage networks are not isolated from other traffic types, this is a finding. If IP-based storage is not used, this is not applicable.
Fix Text
Configuration of an IP-Based VMkernel will be unique to each environment but for example to modify the IP address and VLAN information to the correct network on a standard switch for an iSCSI VMkernel do the following: From the vSphere Web Client select the ESXi host and go to Configure >> Networking >> VMkernel adapters. Select the Storage VMkernel (for vSAN only) and click Edit settings >> On the Port properties tab uncheck everything but "vSAN.” On the IP Settings tab >> Enter the appropriate IP address and subnet information and click OK. Set the appropriate VLAN ID >> Configure >> Networking >> Virtual switches. Select the Storage portgroup (iSCSI, NFS, vSAN) and click Edit settings >> On the properties tab, enter the appropriate VLAN ID and click OK.
Additional Identifiers
Rule ID: SV-207650r854582_rule
Vulnerability ID: V-207650
Group Title: SRG-OS-000423-VMM-001700
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-002418 |
The information system protects the confidentiality and/or integrity of transmitted information. |
Controls
Number | Title |
---|---|
SC-8 |
Transmission Confidentiality And Integrity |