Check: SLEM-05-252010
SUSE Linux Enterprise Micro (SLEM) 5 STIG:
SLEM-05-252010
(in version v1 r1)
Title
SLEM 5 clock must, for networked systems, be synchronized to an authoritative DOD time source at least every 24 hours. (Cat II impact)
Discussion
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
Check Content
Verify that SLEM 5 clock must be configured to synchronize to an authoritative DOD time source when the time difference is greater than one second with the following command: > sudo grep maxpoll /etc/chrony.conf server 0.us.pool.ntp.mil maxpoll 16 If the "server" parameter is not set to an authoritative DOD time source, "maxpoll" is greater than "16", the line is commented out, or the line is missing, this is a finding.
Fix Text
SLEM 5 clock must be configured to synchronize to an authoritative DOD time source when the time difference is greater than one second. To configure the system clock to synchronize to an authoritative DOD time source at least every 24 hours, edit the file "/etc/chrony.conf". Add or correct the following lines by replacing "<time_source>" with an authoritative DOD time source: server <time_source> maxpoll 16
Additional Identifiers
Rule ID: SV-261311r996404_rule
Vulnerability ID: V-261311
Group Title: SRG-OS-000355-GPOS-00143
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001891 |
The information system compares internal information system clocks on an organization-defined frequency with an organization-defined authoritative time source. |
CCI-002046 |
The information system synchronizes the internal system clocks to the authoritative time source when the time difference is greater than the organization-defined time period. |
Controls
Number | Title |
---|---|
AU-8(1) |
Synchronization with Authoritative Time Source |