Check: TIDX-SV-000011
Trellix TIE/DXL STIG:
TIDX-SV-000011
(in versions v2 r2 through v1 r0.1)
Title
The Advanced Threat Defense (ATD) Maximum Queue Size must be configured. (Cat II impact)
Discussion
McAfee ATD is a separate McAfee product which enables organizations to detect advanced, evasive malware and convert threat information into action and protection. It includes additional inspection capabilities that broaden detection and expose evasive threats. It integrates with other McAfee security solutions, one of which is the McAfee TIE server. This requirement is to be configured if the organization has the McAfee ATD solution implemented as part of their security infrastructure.
Check Content
If the organization has not implemented the McAfee ATD as part of their security infrastructure, this is Not Applicable. This check needs to be completed for the active McAfee TIE Server Management policy that manages the site McAfee TIE. From the ePO server console, select the Policy Catalog tab. From the Policy Catalog, select the McAfee TIE Server Management from Products. Under "Actions", select Edit for the policy that manages the site McAfee TIE. Select the "Sandboxing" tab. Under McAfee Advanced Threat Defense, verify the "Maximum Queue Size" under "Connection Settings" is configured. If the "Maximum Queue Size" is not configured, this is a finding.
Fix Text
This check needs to be completed for the active McAfee TIE Server Management policy that manages the site McAfee TIE. From the ePO server console, select the Policy Catalog tab. From the Policy Catalog, select the McAfee TIE Server Management from Products. Under "Actions", select Edit for the policy that manages the site McAfee TIE. Select the "Sandboxing" tab. Under McAfee Advanced Threat Defense, configure the "Maximum Queue Size" under "Connection Settings".
Additional Identifiers
Rule ID: SV-222007r506938_rule
Vulnerability ID: V-222007
Group Title: SRG-APP-000516
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000366 |
Implement the security configuration settings. |
Controls
Number | Title |
---|---|
CM-6 |
Configuration Settings |