Check: IDNS-8X-700001
Infoblox 8.x DNS STIG:
IDNS-8X-700001
(in version v1 r1)
Title
The Infoblox DNS server must implement NIST FIPS-validated cryptography for provisioning digital signatures, generating cryptographic hashes, and protecting unclassified information requiring confidentiality. (Cat I impact)
Discussion
Use of weak or untested encryption algorithms undermines the purposes of using encryption to protect data. The application must implement cryptographic modules adhering to the higher standards approved by the federal government since this provides assurance they have been tested and validated.
Check Content
Note: For Infoblox DNS systems on a classified network, this requirement is Not Applicable. Note: For Infoblox Grids that run in FIPS mode, this requirement is Not Applicable. Refer to the Administrator Guide for more information on FIPS Mode. 1. Navigate to Data Management >> DNS >> Grid DNS properties. 2. Toggle Advanced Mode and click on the "DNSSEC" tab. 3. Validate that all Key Signing Keys (KSKs) and Zone Signing Keys (ZSKs) use FIPS-approved algorithms. 4. When complete, click "Cancel" to exit the "Properties" screen. If non-FIPS-approved algorithms are in use, this is a finding.
Fix Text
Note: Ensure DNSSEC is configured to meet all other STIG requirements prior to signing a zone to avoid signing with an unapproved configuration. 1. Navigate to Data Management >> DNS >> Grid DNS properties. 2. Toggle Advanced Mode and click on the "DNSSEC" tab. 3. Configure FIPS-compliant algorithms. 4. Follow manual key rollover procedures and update all non-compliant KSKs and ZSKs to use FIPS-approved algorithms.
Additional Identifiers
Rule ID: SV-233906r621666_rule
Vulnerability ID: V-233906
Group Title: SRG-APP-000514-DNS-000075
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-002450 |
The information system implements organization-defined cryptographic uses and type of cryptography required for each use in accordance with applicable federal laws, Executive Orders, directives, policies, regulations, and standards. |
Controls
Number | Title |
---|---|
SC-13 |
Cryptographic Protection |