Check: IIST-SI-000235
Microsoft IIS 10.0 Site STIG:
IIST-SI-000235
(in versions v2 r10 through v2 r3)
Title
The Idle Time-out monitor for each IIS 10.0 website must be enabled. (Cat II impact)
Discussion
The idle time-out attribute controls the amount of time a worker process will remain idle before it shuts down. A worker process is idle if it is not processing requests and no new requests are received. The purpose of this attribute is to conserve system resources; the default value for idle time-out is 20 minutes. By default, the World Wide Web (WWW) service establishes an overlapped recycle, in which the worker process to be shut down is kept running until after a new worker process is started.
Check Content
If this IIS 10.0 installation is supporting Microsoft Exchange, and not otherwise hosting any content, this requirement is Not Applicable. Follow the procedures below for each site hosted on the IIS 10.0 web server: Open the IIS 10.0 Manager. Click the Application Pools. Highlight an Application Pool to review and click "Advanced Settings" in the "Actions" pane. Scroll down to the "Process Model" section and verify the value for "Idle Time-out" is not "0". If the "Idle Time-out" is set to "0", this is a finding.
Fix Text
Follow the procedures below for each site hosted on the IIS 10.0 web server: Open the IIS 10.0 Manager. Click the Application Pools. Highlight an Application Pool to review and click "Advanced Settings" in the "Actions" pane. Scroll down to the "Process Model" section and set the value for "Idle Time-out" to something other than "0". "20" or less is recommended if the amount of RAM on the system is limited.
Additional Identifiers
Rule ID: SV-218762r962268_rule
Vulnerability ID: V-218762
Group Title: SRG-APP-000295-WSR-000012
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-002361 |
Automatically terminate a user session after organization-defined conditions or trigger events requiring session disconnect. |
Controls
Number | Title |
---|---|
AC-12 |
Session Termination |