Check: RACF-OS-000190
IBM z/OS RACF STIG:
RACF-OS-000190
(in versions v8 r14 through v7 r1)
Title
IBM z/OS SNTP daemon (SNTPD) permission bits must be properly configured. (Cat II impact)
Discussion
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time, a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
Check Content
From the ISPF Command Shell enter: cd /usr/sbin ls -al If the following File permission and user Audit Bits are true, this is not a finding. /usr/sbin/sntpd 1740 faf The following represents a hierarchy for permission bits from least restrictive to most restrictive: 7 rwx (least restrictive) 6 rw- 3 -wx 2 -w- 5 r-x 4 r-- 1 --x 0 --- (most restrictive) The possible audit bits settings are as follows: f log for failed access attempts a log for failed and successful access - no auditing
Fix Text
With the assistance of a systems programmer with UID(0) and/or SUPERUSER access, configure the UNIX permission bits and user audit bits on the SNTPD to conform to the specifications below: /usr/sbin/sntpd 1740 faf
Additional Identifiers
Rule ID: SV-223775r877038_rule
Vulnerability ID: V-223775
Group Title: SRG-OS-000355-GPOS-00143
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001891 |
The information system compares internal information system clocks on an organization-defined frequency with an organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
AU-8 (1) |
Synchronization With Authoritative Time Source |