Check: AIX7-00-003057
IBM AIX 7.x STIG:
AIX7-00-003057
(in versions v2 r9 through v1 r1)
Title
The timed daemon must be disabled on AIX. (Cat II impact)
Discussion
This is the old UNIX time service. The timed daemon is the old UNIX time service. Disable this service and use xntp, if time synchronization is required in the environment.
Check Content
From the command prompt, execute the following command: # grep "^start[[:blank:]]/usr/sbin/timed" /etc/rc.tcpip If there is any output from the command, this is a finding.
Fix Text
In "/etc/rc.tcpip", comment out the "timed" entry by running command: # chrctcp -d timed
Additional Identifiers
Rule ID: SV-215363r508663_rule
Vulnerability ID: V-215363
Group Title: SRG-OS-000095-GPOS-00049
Expert Comments
Expert comments are only available to logged-in users.
CCIs
CCIs tied to check.
Number | Definition |
---|---|
CCI-000381 |
The organization configures the information system to provide only essential capabilities. |
Controls
Controls tied to check. These are derived from the CCIs shown above.
Number | Title |
---|---|
CM-7 |
Least Functionality |