Check: SRG-OS-000355-GPOS-00143
General Purpose Operating System SRG:
SRG-OS-000355-GPOS-00143
(in version v3 r1)
Title
The operating system must, for networked systems, compare internal information system clocks at least every 24 hours with a server which is synchronized to one of the redundant United States Naval Observatory (USNO) time servers, or a time server designated for the appropriate DOD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS). (Cat II impact)
Discussion
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
Check Content
Verify the operating system, for networked systems, compares internal information system clocks at least every 24 hours with a serve synchronized to one of the redundant United States Naval Observatory (USNO) time servers, or a time server designated for the appropriate DOD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS). If it does not, this is a finding.
Fix Text
Configure the operating system to, for networked systems, compare internal information system clocks at least every 24 hours with a server synchronized to one of the redundant United States Naval Observatory (USNO) time servers, or a time server designated for the appropriate DOD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS).
Additional Identifiers
Rule ID: SV-203711r982208_rule
Vulnerability ID: V-203711
Group Title: SRG-OS-000355
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-004923 |
Compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
No controls are assigned to this check |