Check: SRG-APP-000119-AU-000110
Central Log Server SRG:
SRG-APP-000119-AU-000110
(in versions v2 r2 through v1 r3)
Title
The Central Log Server must protect audit information from unauthorized modification. (Cat II impact)
Discussion
If audit data were to become compromised, then forensic analysis and discovery of the true source of potentially malicious system activity is impossible to achieve. To ensure the veracity of audit data, the information system and/or the application must protect audit information from unauthorized modification. This requirement can be achieved through multiple methods, which will depend upon system architecture and design. Some commonly employed methods include ensuring log files receive the proper file system permissions, and limiting log data locations. Applications providing a user interface to audit data will leverage user permissions and roles identifying the user accessing the data and the corresponding rights that the user enjoys in order to make access decisions regarding the modification of audit data. Audit information includes all information (e.g., audit records, audit settings, and audit reports) needed to successfully audit information system activity.
Check Content
Examine the configuration. Verify that the Central Log Server is configured to protect audit information from any unauthorized modification. If the Central Log Server is not configured to protect audit information from any unauthorized modification, this is a finding.
Fix Text
Configure the Central Log Server to protect audit information from unauthorized modification.
Additional Identifiers
Rule ID: SV-221915r420089_rule
Vulnerability ID: V-221915
Group Title: SRG-APP-000119
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-000163 |
The information system protects audit information from unauthorized modification. |
Controls
Number | Title |
---|---|
AU-9 |
Protection Of Audit Information |