Check: SRG-APP-000225-AS-000154
Application Server SRG:
SRG-APP-000225-AS-000154
(in versions v4 r2 through v2 r2)
Title
The application server must provide a clustering capability. (Cat II impact)
Discussion
This requirement is dependent upon system MAC and confidentiality. If the system MAC and confidentiality levels do not specify redundancy requirements, this requirement is NA. Failure to a known secure state helps prevent a loss of confidentiality, integrity, or availability in the event of a failure of the information system or a component of the system. When application failure is encountered, preserving application state facilitates application restart and return to the operational mode of the organization with less disruption of mission/business processes. Clustering of multiple application servers is a common approach to providing fail-safe application availability when system MAC and confidentiality levels require redundancy.
Check Content
This requirement is dependent upon system MAC and confidentiality. If the system MAC and confidentiality levels do not specify redundancy requirements, this requirement is NA. Review the application server configuration and documentation to ensure the application server is configured to provide clustering functionality. If the application server is not configured to provide clustering or some form of failover functionality, this is a finding.
Fix Text
This requirement is dependent upon system MAC and confidentiality. If the system MAC and confidentiality levels do not specify redundancy requirements, this requirement is NA. Configure the application server to provide application failover or participate in an application cluster which provides failover.
Additional Identifiers
Rule ID: SV-204768r961122_rule
Vulnerability ID: V-204768
Group Title: SRG-APP-000225
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001190 |
Fail to an organization-defined known-system state for the list of organization-defined types of system failures on organization-defined system components on the indicated components while preserving organization-defined system state information in failure. |
Controls
Number | Title |
---|---|
SC-24 |
Fail in Known State |