Check: SRG-APP-000371-AS-000077
Application Server SRG:
SRG-APP-000371-AS-000077
(in versions v3 r4 through v2 r2)
Title
The application server must compare internal application server clocks at least every 24 hours with an authoritative time source. (Cat II impact)
Discussion
Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronization of system clocks is needed in order to correctly correlate the timing of events that occur across multiple systems. To meet this requirement, the organization will define an authoritative time source and have each system compare its internal clock at least every 24 hours.
Check Content
Review application server documentation and confirm that the application server compares internal application server clocks at least every 24 hours with an authoritative time source. If the application server does not compare internal application server clocks to an authoritative source or if the frequency is greater than every 24 hours, this is a finding.
Fix Text
Configure the application server to compare internal application server clocks at least every 24 hours with an authoritative time source.
Additional Identifiers
Rule ID: SV-204792r879744_rule
Vulnerability ID: V-204792
Group Title: SRG-APP-000371
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-001891 |
The information system compares internal information system clocks on an organization-defined frequency with an organization-defined authoritative time source. |
Controls
Number | Title |
---|---|
AU-8 (1) |
Synchronization With Authoritative Time Source |