Check: APSC-DV-001930
Application Security and Development STIG:
APSC-DV-001930
(in versions v5 r3 through v4 r2)
Title
Applications used for non-local maintenance sessions must audit non-local maintenance and diagnostic sessions for organization-defined auditable events. (Cat II impact)
Discussion
Non-local maintenance and diagnostic activities are those activities conducted by individuals communicating through a network, either an external network (e.g., the Internet) or an internal network. Local maintenance and diagnostic activities are those activities carried out by individuals physically present at the information system or information system component and not communicating across a network connection. If events associated with non-local administrative access or diagnostic sessions are not logged and audited, a major tool for assessing and investigating attacks would not be available. This requirement addresses auditing-related issues associated with maintenance tools used specifically for diagnostic and repair actions on organizational information systems. This requirement applies to hardware/software diagnostic test equipment or tools. This requirement does not cover hardware/software components that may support information system maintenance, yet are a part of the system (e.g., the software implementing "ping," "ls," "ipconfig," or the hardware and software implementing the monitoring port of an Ethernet switch).
Check Content
Review the application documentation and interview the application administrator to identify application maintenance functions. If the application does not provide non-local maintenance and diagnostic capability, this requirement is not applicable. Identify the maintenance functions/capabilities that are provided by the application and performed by an individual which can be performed remotely. For example, the application may provide the ability to clean up a folder of temporary files, add users, remove users, restart processes, backup certain files, manage logs, or execute diagnostic sessions. Identify and open the audit logs that capture maintenance actions performed by the application. Accessing the application in the appropriate role to execute maintenance tasks, perform several maintenance tasks and observe the logs. If the application provides maintenance functions and capabilities and those functions are not logged when they are executed, this is a finding.
Fix Text
Configure the application to log when application maintenance functionality is executed remotely.
Additional Identifiers
Rule ID: SV-222561r879782_rule
Vulnerability ID: V-222561
Group Title: SRG-APP-000409
Expert Comments
CCIs
Number | Definition |
---|---|
CCI-002884 |
The organization audits nonlocal maintenance and diagnostic sessions^ organization-defined audit events. |
Controls
Number | Title |
---|---|
MA-4 (1) |
Auditing And Review |